Re: [fluka-discuss]: spallation neutron spectrum

From: Vittorio Boccone <dr.vittorio.boccone_at_ieee.org>
Date: Thu, 7 Jul 2016 21:13:01 +0200

Hi Pradeep,
  Yes you are scoring the one way current out of target to vacuum. If this is what you need you are on the right track. You can increase the number of bins and eventually place the default to “precisio” instead of “new-defa”. I don’t see any mistakes in your simulation.

Best,
Vittorio

> On 07 Jul 2016, at 11:48, baraila_at_barc.gov.in wrote:
>
> Dear FLUKA experts,
> I am Pradeep Baraila from India. I am studying spallation using FLUKA. A pencil proton beam of 1.0 GeV hits a cylindrical target of lead along the axis of target. I am interested in the leaked neutron spectrum.The input file is attached herewith this mail. I am not sure whether this is the correct way to get spallation neutron spectrum. Please help me.
>
> Thanks.<fast_ADS_target.inp>