Quoting Francesco Cerutti <Francesco.Cerutti_at_cern.ch>:
> Dear Mahmoudreza,
>
> exactly, this is what I mean.
>
> (Unless you lower on purpose the BME-RQMD switch energy set at 125
> MeV/n - and/or change the respective smearing set at +-25 MeV/n - by
> means of the PHYSICS card, but this has nothing to do with the Bragg
> peak position).
>
> Best
>
> Francesco
>
> **************************************************
> Francesco Cerutti
> CERN-EN/STI
> CH-1211 Geneva 23
> Switzerland
> tel. ++41 22 7678962
> fax ++41 22 7668854
>
> On Tue, 31 Jan 2017, Mrakbari2015_at_ast.ui.ac.ir wrote:
>
>> Hello Dear Francesco
>> You mean that RQMD model will not be activated or implemented (evev if by
>> linking it) at 100 MeV/n carbon ion Beam?
>> and FLUAK uses BME model at 100 MeV/n by defaut without considering of my
>> linking to the RQMD libraries?
>>
>> Best Wishes
>> Mahmoudreza
>>
>>
>
> __________________________________________________________________________You can manage unsubscription from this mailing list at
> https://www.fluka.org/fluka.php?id=acc_info
Dear Francesco,
Thank you very much. It is more clear now.
Kind regards,
Mahmoudreza
__________________________________________________________________________
You can manage unsubscription from this mailing list at
https://www.fluka.org/fluka.php?id=acc_info
Received on Sun Feb 05 2017 - 01:24:05 CET