From: Alfredo Ferrari (alfredo.ferrari@cern.ch)
Date: Wed Aug 04 2004 - 09:53:26 CEST
The id's for NITROGEN changed. Do you have a LOW-MAT card for NITROGEN?
If so the second id should become -2 as per the list in the new manual.
Alfredo
On Tue, 3 Aug 2004, Georgios Tsiledakis wrote:
>
> Dear all,
> I have just downloaded the latest version of FLUKA (flukalinuxAA.tar).
> When I run the same input file I was using with success during the
> previous FLUKA release,...,despite the fact that I have modified all
> the scoring routines according to the newest versions, I had an error...
> The .out file finishes as following:
>
> ***** Neutron Xsec: ****
> **** Group limits, average energies, velocities ....
>
> *** Recoil proton production activated for Morse mat. # 1 ***
> **** Low energy neutron xsec not found for some media 32 33 ****
> .....................................
> Does this imply anything??
> The 32, 33 are the number indexes in the MATERIAL card for 132-Xenon and
> 134-Xenon isotopes respectively...
> I have no idea what else has changed...
> Thank you very much in advance.
> Kind regards
> Georgios
>
-- +----------------------------------------------------------------------------+ | Alfredo Ferrari || Tel.: +41.22.767.6119 | | CERN-AB || Fax.: +41.22.767.7555 | | 1211 Geneva 23 || e-mail: Alfredo.Ferrari@cern.ch | | Switzerland || Alfredo.Ferrari@mi.infn.it | +----------------------------------------------------------------------------+