Re: [fluka-discuss]: estimation of total dose-eq in each region?

From: Andrea Fontana <andrea.fontana_at_pv.infn.it>
Date: Mon, 17 Apr 2017 11:15:40 +0200

Hello Hamed,
    please keep the replies within the discussion list, as the topic
might be
of interest also for others.

Regarding you questions:
1) if you are interested in numbers, you could save your results in a
formatted
    (ASCII) format to read the results directly. No plots are needed in
this case.

2) you can alse use SCORE, with all the warnings given in the manual:
SCORE and
    USRBIN per region give exactly the same output, but with score
(andEVENTDAT)
    many more information is written in the file and you might generate
very big
    data files.

Kind regards,
Andrea

Il 17/04/2017 10:09, hamed.feizi_at_sci.uk.ac.ir ha scritto:
>
> Dear Andrea,
>
> Thank you very much for your reply. It helped me a lot. I just have
> two another questions. 1- If I use the USRBIN card (by region) in
> order to estimate the equivalent dose, How can I get the results? I
> ask this quastion because I run the code secesfully but I could not
> get the results or plot them by flair (in this case I just need the
> total equivalent dose in each region which actully leads to 15
> numbers). 2- Since the incident particles are photons (E = 200 keV);
> can I use SCORE card in order to score energy deposition in each
> region and then calculate dose equvalent?
>
> Sincerely yours,
>
> Hamed.
>
> > Dear Hamed,
> > with the USRBIN card it is possible to score the dose equivalent
> > by region in two ways, depending on the particles that you are
> > interested in:
> >
> > - with the generalized particle DOSE-EQ (particle number 240)
> > FLUKA calculates for each region the particle fluence weighted by
> > various sets of conversion coefficients that depend both on the organ
> > and on the radiation type. These coefficients are available only
> > for neutrons, protons, charged pions, muons, photons and electrons.
> > You can also choose among different options with the AUXSCORE card,
> > as explained in the manual. The result is in picoSieverts per primary.
> >
> > - with the generalized particle DOSEQLET (particle number 243) FLUKA
> > calculates the dose equivalent as deļ¬ned by ICRU: H = D x Q(L), where
> > L is the unrestricted Linear Energy Transfer in water, for particles
> > for which conversion coefficients are not available, typically heavy
> > ions. In this case the units are GeV/g per primary times the quality
> > factor Q(LET).
> >
> > So the choice depends on the particles you are scoring and the best
> > way is to try both scorers in your geometry and to inspect the results.
> >
> > Also note that, for region-dependent USRBIN scoring, the region volume
> > is not taken into account by FLUKA, even if entered explicitely
> > in the geometry section.
> >
> > Kind regards,
> > Andrea
> >
> >
> >
> > Il 16/04/2017 13:15, hamed.feizi_at_sci.uk.ac.ir ha scritto:
> >>
> >> Dear FLUKA experts,
> >>
> >> I have simulated a human phantom and I intend to estimate the total
> >> equivalent dose in each region (the number of regions are 15).
> >> Unfortunately, I have serious problems with this issue. Since the
> >> _total_ equivalent dose is desire, I think I should use USRBIN card
> >> with what1=12 (by region). If so, how can I reach the results (because
> >> in this case, I only nead total equivalent dose in each region=15
> >> numbers). Is this correct? Which one should I use? DOSE-EQ or
> >> DOSEQULET? I would be grateful if anybody can attach an input file
> >> which can do such simulation.
> >> Best Regards,
> >> Hamed.
> >>
> >
> > --
> > ========================================================================
> > Dr. Andrea Fontana tel: +39 0382 987991
> > Istituto Nazionale fax: +39 0382 423241
> > di Fisica Nucleare
> > Sezione di Pavia e-mail: andrea.fontana_at_pv.infn.it
> > Via Bassi 6 web : www.pv.infn.it/~fontana
> > 27100 PAVIA, Italy
> > ========================================================================
> >
> >
> __________________________________________________________________________
> > You can manage unsubscription from this mailing list at
> > https://www.fluka.org/fluka.php?id=acc_info
> >
> >
>

-- 
========================================================================
Dr. Andrea Fontana                    tel: +39 0382 987991
Istituto Nazionale                    fax: +39 0382 423241
di Fisica Nucleare
Sezione di Pavia                      e-mail: andrea.fontana_at_pv.infn.it
Via Bassi 6                           web   : www.pv.infn.it/~fontana
27100 PAVIA, Italy
========================================================================