Re: [fluka-discuss]: depth dose for 310 MeV/n carbon beam

From: <mrakbari2015_at_ast.ui.ac.ir>
Date: Tue, 18 Apr 2017 23:24:34 +0430

  Hello Dear Francesco
I have not seen your answer since that time.
Thanks alot
Best Regards

Quoting Francesco Cerutti <Francesco.Cerutti_at_cern.ch>:

> Hallo,
>
> I already answered you two months ago
>
> http://www.fluka.org/web_archive/earchive/new-fluka-discuss/9870.html
> http://www.fluka.org/web_archive/earchive/new-fluka-discuss/9866.html
> (second point)
>
> and you keep restricting your scoring within 1 mm lateral dimension
> (in x) instead of extending it as previously explained.
>
> Best wishes
>
> Francesco
>
> **************************************************
> Francesco Cerutti
> CERN-EN/STI
> CH-1211 Geneva 23
> Switzerland
> tel. ++41 22 7678962
> fax  ++41 22 7668854
>
> On Mon, 17 Apr 2017, mrakbari2015_at_ast.ui.ac.ir wrote:
>
>> Dear FLUKA experts
>> I am simulating the depth dose of a 310 MeV/n carbon beam.
>> but the result does not have agreement with exprimental data! (see the
>> attached file:red line is expriment and the other is simulation)
>> input file is attached
>> would you please help me calculate the more accurate depth dose?
>> Best
>>  
>
>  


__________________________________________________________________________
You can manage unsubscription from this mailing list at https://www.fluka.org/fluka.php?id=acc_info
Received on Tue Apr 18 2017 - 22:27:56 CEST