Using DOSE-EQ with USRYIELD

From: Burge, F (Frances) <frances.burge_at_diamond.ac.uk>
Date: Tue, 24 Mar 2009 14:59:35 -0000

Dear Fluka users,
  I would like to use the USRYIELD card together with AUXSCORE to
convert a photon fluence yield to dose equivalent around a lead target.
So I have set up the following cards in my input file:

USRYIELD 124 DOSE-EQ -24 LeadTarg Outervac 1.0 Flu_dos1
USRYIELD 180. 0. 180. 3. 0. 6. &
AUXSCORE USRYIELD PHOTON Flu_dos1 EWT74

My first USRYIELD variable is lab polar angle in degrees, from 0 - 180,
the second is particle energy with a single bin. I want to score dose
equivalent in each of the angular bins if that is possible. The target
is simply a ZCC, and the primary beam is travelling along the z axis.
The quantity scored in USRYIELD is a double differential fluence yield,
which if I was just scoring photons (rather than dose-eq) would be
[photons/GeV/sr/cos theta].

Now I guess what I get from the above cards is something like [pSv.cm2
/GeV/sr] because of the folding of the dose coefficients with the
fluence scoring.

So the question is: If I normalise to the surface area of the lead
target, will I be scoring the correct dose angular distribution in
pSv/GeV/sr ? Or is the above combination of cards meaningless ?

thanks for any suggestions,
Frances

Frances Burge
Health Physicist
01235 778269
Diamond Light Source Ltd.
Harwell Science and Innovation Campus
Didcot
Oxfordshire
OX11 0DE
 
 
This e-mail and any attachments may contain confidential, copyright and or privileged material, and are for the use of the intended addressee only. If you are not the intended addressee or an authorised recipient of the addressee please notify us of receipt by returning the e-mail and do not use, copy, retain, distribute or disclose the information in or attached to the e-mail.
Any opinions expressed within this e-mail are those of the individual and not necessarily of Diamond Light Source Ltd.
Diamond Light Source Ltd. cannot guarantee that this e-mail or any attachments are free from viruses and we cannot accept liability for any damage which you may sustain as a result of software viruses which may be transmitted in or with the message.
Diamond Light Source Limited (company no. 4375679). Registered in England and Wales with its registered office at Diamond House, Harwell Science and Innovation Campus, Didcot, Oxfordshire, OX11 0DE, United Kingdom
 
Received on Tue Mar 24 2009 - 21:46:25 CET

This archive was generated by hypermail 2.2.0 : Tue Mar 24 2009 - 21:46:25 CET