Hi Luis,
your input file looks correct to me. I made a quick test run changing
your BEAMPOS card and placing it in x=0.0, very close to the regions
where you are scoring residual nuclei. This way I could see some
results.
So probably the fact that you have an empty file is due to a poor
statistics, you can try to run more primary histories or apply some
biasing techniques to your simulation.
Lucia
On Mar 24, 2009 05:57 PM, "Fernandez-Hernando, JL (Juan)"
<juan.fernandez-hernando_at_stfc.ac.uk> wrote:
> Dear FLUKA users,
> despite getting results of residual equivalent dose rate from the
> USRBINs I do not get any activated products in my resnuclei sum.lis
> file. I do not know what is wrong with it, if anyone could give me a
> hint, perhaps I'm missing some card or the physics in my input are
> wrong.
> Find attached my input file together with the .lis files that resulted
> from the simulation.
> Thanks a lot!
>
> Luis
Received on Thu Mar 26 2009 - 16:55:27 CET
This archive was generated by hypermail 2.2.0 : Thu Mar 26 2009 - 16:55:27 CET