They are normalized by the volume you provide in the RESNUCLEI
card (default=1 if not provided).
If the manual is not clear on this topic, please point us to the
misleading statements so that we can better phrase them
Alfredo
+----------------------------------------------------------------------+
| Alfredo Ferrari || Tel.: +41.22.76.76119 |
| CERN-EN/STI || Fax.: +41.22.76.69474 |
| 1211 Geneva 23 || e-mail: Alfredo.Ferrari_at_cern.ch |
| Switzerland || |
+----------------------------------------------------------------------+
On Fri, 1 Jul 2011, mir inamul haq jeri wrote:
> Hello,
> I want to know if the resnuclei output results are normalized per unit
> volume which we provide as input in RESNUCLE card or the results are
> integrated for the given region and volume.From the manual it seems that the
> results should be integrated for the given region but i was pondering why we
> need to provide the input volume if we are specifying the region.
> Thank you
>
> --
> MIR INAMUL HAQ JERI
> INSTN SACLAY.
> UNIVERSITY OF PARIS SUD 11.
>
Received on Sat Jul 02 2011 - 23:32:27 CEST
This archive was generated by hypermail 2.2.0 : Sat Jul 02 2011 - 23:32:28 CEST