I seem to have found the source of the problem. It is something to do with
a number limit on the number of irradiation intervals I have specified?
I believe FLUKA will accept up to 2500 irradiation intervals (around 830 IRRPROFI cards),
I only have 600 intervals so I wonder why I am suffering this problem, and only
with RESNUCLE cards, only when they are associated with a DCYSCORE?
Thanks in advance,
Lewis.
-----Original Message-----
From: owner-fluka-discuss_at_mi.infn.it [mailto:owner-fluka-discuss_at_mi.infn.it] On Behalf Of Macfarlane, Lewis
Sent: 27 February 2012 18:21
To: fluka-discuss_at_fluka.org
Subject: Problem Processing RESNUCLEI Files with DCYSCORE
Dear Experts,
As per the title, I'm having trouble processing results.
My case runs just fine and I have no problem processing USRBIN, USRTRACK etc
that are linked with DCYSCORE cards. I also have no problem processing RESNUCLEI
outputs that are not linked to a DCYSCORE card. However as soon as
I introduce a DCYSCORE card associated with a RESNUCLEI card, my RESNUCLEI
results fail upon processing, with the following error:
Subscript out of range on file line 188, procedure usrsuw.f/MAIN. Attempt
to access the 301-th element of variable birhlp.
If anyone could offer any help, that would be great,
Many thanks,
Lewis.
Received on Tue Feb 28 2012 - 15:26:31 CET
This archive was generated by hypermail 2.2.0 : Tue Feb 28 2012 - 15:26:43 CET