Dear Mikhail, Dear Alberto,
Thank you both for your hints.
I'll try it via DOSE and EM-DOSE scoring with high Delta-Ray production
threshold, that way fits my current input file best.
One more question to DISCARD: When i discard the protons, will their
energy also be discarded?
I thought it would be locally deposited just like when a particle's
energy falls below the transport threshold.
Regards
Felix
Am 2015-02-13 11:50, schrieb Felix Ernst Horst:
> Dear FLUKA experts,
>
> I am currently simulating the absorbed dose profile from neutrons
> (spectrum from ~10 MeV down to thermal energies) in a water phantom by
> USRBIN.
> That dose distribution should consist of amounts from recoil nuclei
> (in water mainly recoil protons) and gamma photons from neutron
> capture (in water mainly on hydrogen) respectively their secondary
> electrons. Is it possible to separate these two dose components from
> each other (e.g. by switching off one of these two interaction
> mechanisms while the other remains switched on)?
> Which physic cards are responsible for these two mechanisms?
>
> Thank you
> Regards
>
> Felix
--