Re: [fluka-discuss]: 1keV neutron fluence in water

From: Vittorio Boccone <dr.vittorio.boccone_at_ieee.org>
Date: Thu, 15 Sep 2016 21:01:42 +0200

Hi Nima, sounds nice. Still a good 'ol “isolethargic” plot would allow you
to compare slope which are impossible to perceive with the linear scale(s).

Best,
Vittorio

On Thu, Sep 15, 2016 at 8:19 PM, Nima Ghal-Eh <Nima.Ghal-Eh_at_fuw.edu.pl>
wrote:

> Dear Vittorio,
>
> Thanks for your comment. As you may see in the attached file, the neutron
> fluence calculations undertaken with MCNPX F4 tally and FLUKA usrtrack card
> (when multiplied by energy bin width)represent a good agreement (for a 1keV
> neutron source located at the center of 10-cm light water sphere).
>
> Best regards,
> Nima.