[ <--- prev -- ] [ HOME ] [ -- next ---> ] EMFFLUOActivates a detailed treatment of photoelectric interactions and of
the following atomic deexcitation, with production of fluorescence
X-rays (and a rough treatment of Auger electrons)
WHAT(1) >= 0: set fluorescence on < 0 : set fluorescence off = 0 : ignored Default = -1.0 (no fluorescence) if option DEFAULTS is not used, or if it is used with anything but CALORIMEtry, EM-CASCAde, ICARUS or PRECISIOn. If DEFAULTS is used with a SDUM value equal to one of the latter, the default is 1.0 (fluorescence on). WHAT(2) = lower bound (or corresponding name) of the material indices in which fluorescence is activated ("From material WHAT(2)...") Default = 3. WHAT(3) = upper bound (or corresponding name) of the material indices in which fluorescence is activated ("... to material WHAT(3)...") Default = WHAT(2) WHAT(4) = step length in assigning indices ("...in steps of WHAT(4)") Default = 1. WHAT(5), WHAT(6), SDUM : not used Default (option EMFFLUO not requested): fluorescence is not simulated unless option DEFAULTS is chosen with SDUM = CALORIMEtry, EM-CASCAde, ICARUS or PRECISIOn. Notes:
Example (number-based): *...+....1....+....2....+....3....+....4....+....5....+....6....+....7....+....8 EMF EMFCUT 1.E-5 1.E-5 0.0 17. 18. EMFFLUO 1.0 17. 18. * In the above example, the user activates fluorescence production in * Lead and Tantalum (standard FLUKA material numbers 17 and 18). The * photon and electron cutoff has been set at 10 keV (the K-edge for * Pb and Ta is of the order of 100 keV). The same example, name-based: EMF EMFCUT 1.E-5 1.E-5 0.0 LEAD TANTALUM EMFFLUO 1.0 LEAD TANTALUM |