Re: urgent:RADDECAY problems

From: Stefan Roesler (sroesler@mail.cern.ch)
Date: Wed Jul 12 2006 - 09:31:07 CEST

  • Next message: Guo Wen: "online fluscw.f"

    Hi,

    The SDUM in DCYSCORE has to be aligned with column 71 while yours starts
    in column 72.

    please use

    DCYSCORE 1.0 0.0 0.0 1.0 1.0 1.0USRBIN
    DCYSCORE 2.0 0.0 0.0 2.0 2.0 1.0USRBIN
    DCYSCORE 3.0 0.0 0.0 3.0 3.0 1.0USRBIN
    DCYSCORE 4.0 0.0 0.0 4.0 4.0 1.0USRBIN

    greetings,
    Stefan

    On Tue, 11 Jul 2006, Guo Wen wrote:

    > Dear FLUKA expert:
    > I make another test(the input file attached) to request the
    > decays,but still get the same results:the data at defferent decay
    > times no change.I use a proton source
    > irradiating a lead RPP target and use USRBIN to score dose rate in it
    > at four decay times after irradiated,I use four same USRBIN cards with
    > four output files,the
    > data at four decay times are exactly same,I do not know if there is
    > another switch controling the decays except the RADDECAY card? I would
    > be grateful if you could give me some help.
    >
    >
    >
    > My best regards!
    >
    > guowen
    >

    -- 
    ___________________________________
    Stefan Roesler
    CERN, SC/RP
    CH-1211 Geneva 23
    Switzerland
    Phone:  +41-22-7679891
    Fax:    +41-22-7669639
    E-mail: Stefan.Roesler@cern.ch
    

  • Next message: Guo Wen: "online fluscw.f"

    This archive was generated by hypermail 2.1.6 : Wed Jul 12 2006 - 09:44:36 CEST