RE: [fluka-discuss]: NaI detector response, mgdraw, and endraw

From: Trinh Ngoc-Duy <Ngoc-Duy.Trinh_at_ganil.fr>
Date: Fri, 24 Aug 2018 08:01:37 +0000

Dear A. Sharma,

The Gaussian spread depends on the resolution of each detector. So in order to reproduce this effect, you should apply a convolution of the theoretical spectra with the resolution in the function of energy of your detector (by considering that the count in each theoretical energy bin will be distributed following a Gaussian distribution around the theoretical value).

Duy.

De : owner-fluka-discuss_at_mi.infn.it [mailto:owner-fluka-discuss_at_mi.infn.it] De la part de Aman Sharma
Envoyé : Friday, August 24, 2018 9:12 AM
À : fluka-discuss <fluka-discuss_at_fluka.org>
Objet : Re: [fluka-discuss]: NaI detector response, mgdraw, and endraw

Dear Mikhail and Anton,
In your valuable response to Felicia's problem, I have just a query about the output spectrum you obtained with the help of DETECT card. The spectrum that we observe experimentally by bombarding 661.7 keV photons on NaI detector always comprises of Gaussian spread in full energy peak. How we can obtain the exact spectrum showing Gaussian spread. Could you please share the file using DETECT card for obtaining the results that you have discussed in earlier e-mails.
Thanks & Regards,
A. Sharma




On Thu, Aug 23, 2018 at 4:12 PM Mikhail Polkovnikov <Михаил Полковников> <pmk_at_ihep.ru<mailto:pmk_at_ihep.ru>> wrote:
On 21.08.2018 22:58, Felicia Sutanto wrote:
> Dear FLUKA users,
>
> I am a newbie and I have a question about MGDRAW and ENDRAW.
>
> I am trying to simulate a very simple case (input file is attached):
> 661.7 keV photon at the center of a spherical NaI detector (radius = 5cm)
>
> The purpose of this exercise is only to familiarize myself with the
> collision tape.
> I try to tally the energy deposited by summing over the DTRACK in
> MGDRAW and RULL in the ENDRAW. The result is attached
> (fluka_nai_result.pdf).
>
> I also try to do the same simulation in Geant4 and the result is also
> attached (geant4_nai_result.pdf). It seems that the Compton continuum
> is missing in FLUKA...
>
> Am I supposed to maybe include certain physics in FLUKA?
>
> Best regards,
> FS
>
>
>
>
>
>
Dear Felicia,

You can check an energy deposition process by adding a DETECT card.

*...+....1....+....2....+....3....+....4....+....5....+....6....+....7....+....
DETECT 0.0 1.E-05 1.E-03 1.E-06 1. TARGETEDEP

How do you process the MGDRAW, ENDRAW and EEDRAW entries within the user
routine, and how do you process the collision tape itself? Both DETECT
and user dump work fine for me.


Best regards,

Mikhail


__________________________________________________________________________
You can manage unsubscription from this mailing list at https://www.fluka.org/fluka.php?id=acc_info

________________________________
Préservons notre environnement, n’imprimez ce mail que si nécessaire.
Preserve our environment, print this email only if necessary.

__________________________________________________________________________
You can manage unsubscription from this mailing list at https://www.fluka.org/fluka.php?id=acc_info
Received on Fri Aug 24 2018 - 11:33:43 CEST