Re: {Spam-M} [fluka-discuss]: Radiation filed at 1m from Co-60 and Ir-192 in air

From: <arghyac_at_barc.gov.in>
Date: Fri, 22 Mar 2019 13:24:25 +0530

You need to prepare source spectrum of 192Ir and 60Co via source.f
subroutine and then compile it with corresponding input file.


On 2019-03-22 11:54, Jyoti wrote:
> Dear FLUKA Experts,
> I have a point source(Cs-167). I kept a spherical detector around the
> source at 1m. The medium is air. For this geometry, I calculated the
> energy deposition and hence radiation field at 1m from the point
> source. The input file is attached. The results obtained matched with
> the analytical calculated value.
>
> 1) For the same above scenario, if I take the source of Co-60 instead
> of Cs-137. Then, how to proceed with single input file. The problem I
> am facing it is that Co-60 emits two gamma photons per disintegration.
> 2) Similarly, for Ir-192 how to calculate the radiation field? It
> emits multiple photons per disintegration.
>
> Thank you
>
> With regards,
> Jyoti

__________________________________________________________________________
You can manage unsubscription from this mailing list at https://www.fluka.org/fluka.php?id=acc_info
Received on Fri Mar 22 2019 - 10:15:13 CET

This archive was generated by hypermail 2.3.0 : Fri Mar 22 2019 - 10:15:22 CET