Re: [fluka-discuss]: Fluka cannot work

From: Paola Sala <paola.sala_at_mi.infn.it>
Date: Thu, 5 Mar 2020 16:43:24 +0100

Hello
In the AUXSCORE card one has to input the name or number of an existing
binning. In your input, there is no binning called tDose_xy

On the second input, the card to use for setting emf thresholds is
EMFCUT
not
EMF
Regards
Paola
>
>
> Dear Fluka experts:
>
> Recently, my fluka cannot work and I do not know what's wrong.
> Firstly, When I run rcsbodao39_1.inp, the err shown:
> *** Unable to resolve name element tDose_xy in card ***
> AUXSCORE USRBIN tDose_xy
> AMB74
> *** run stopped ***
>
> then, I update FLUKA to 2020.0 beta.1, it's still this misstake.
> Secondly, I run liner_tf_mg1.inp which have been caculated, the err shown:
> !!!! Old (FLUKA87-92) style photo/electrohadro production no longer
> working !!!!
> Could you please try the two input flies to find the problem?
> Thankyou!!!
>
>
>
>
>
> --
> 祝好!
>
> 中国科学院高能物理研究所
>
> 电话:010-88233110


Paola Sala
INFN Milano
tel. Milano +39-0250317374
tel. CERN +41-227679148

__________________________________________________________________________
You can manage unsubscription from this mailing list at https://www.fluka.org/fluka.php?id=acc_info
Received on Thu Mar 05 2020 - 17:54:45 CET

This archive was generated by hypermail 2.3.0 : Thu Mar 05 2020 - 17:54:48 CET