Dear FLUKA experts,
I'm simulating a proton beam in water with no deltaray production.
DELTARAY -1. WATER WATER
When scoring dose and fluence differential in energy, there is a signal detected in the USRBIN and USRTRACK cards for electrons.
I'm not sure what I may be doing wrong. I have used the DELTARAY card before with no issues. How can I set the simulations for no delta ray production?
Example of input, output and result of USRTRACK card attached.
Many thanks and best wishes,
Ana