Re: [fluka-discuss]: Unit Sv/h

From: angeld <angeld_at_inrne.bas.bg>
Date: Thu, 08 Apr 2021 17:17:47 +0300

Dear Bastian,

Your way of unit conversion is correct. If you want to calculate the dose
rate of all particles I think your detectors are all set.

Regards,
Angel

On Thu, 8 Apr 2021 09:49:55 +0200, Bastian Hesbacher
<bastian.hesbacher_at_stud.tu-darmstadt.de> wrote:
> Dear users,
>
>
>
> I am currently having some issues on how to simulate dose rate with an
> unit of Sv/h or Sv/a.
>
> This is my trial:
>
> I am using the USRBIN card with the setting DOSE-EQ and 50 bins for the
> first detector named Dosis. The second detector named Dosis1 is also
> created with the USRBIN card and the setting DOSE-EQ but with 51 bins.
> After that I am using the AUXSCORE card with the settings USRBIN,
> ALL-PART, AMB74 and for the detectors a setting from Dosis to Dosis1.
>
> After all I know the output of Dosis1 should now be the dose rate with
> an unit of pSv/particle.
>
> Is that correct?
>
> If I now multiply my results of detector dose1 with the beam current
> devided by the elementary charge and multiplied by 3600, I should get
> the results with an unit of pSv/h.
>
> Is this statement correct?
>
>
> For a better overview, you can see the part of the input file in the
> attachment. In this picture one can see aswell some other detectors
> which are based on the same principle than Dosis and Dosis1 but are now
> just comments.
>
>
>
> I hope to receive a reply
>
> Best regards,
>
>
> Bastian Hesbacher

-- 
This message has been scanned for viruses and
dangerous content by MailScanner, and is
believed to be clean.
__________________________________________________________________________
You can manage unsubscription from this mailing list at https://www.fluka.org/fluka.php?id=acc_info
Received on Thu Apr 08 2021 - 18:17:17 CEST

This archive was generated by hypermail 2.3.0 : Thu Apr 08 2021 - 18:17:19 CEST