-- Stefan E. Mueller Department of Information Services and Computing - Computational Science and Institute of Radiation Physics Helmholtz-Zentrum Dresden-Rossendorf Tel: +49 (0351) 260 3847 Stefan.Mueller_at_hzdr.de http://www.hzdr.de Vorstand: Prof. Dr. Sebastian M. Schmidt, Dr. Diana Stiller Vereinsregister: VR 1693 beim Amtsgericht Dresden On Tue, 25 May 2021, Hamideh Jalali wrote: > Dear FLUKA experts > > In the explanation of PHOTONUC card, FLUKA manual says: when selecting the > SDUM=MUMUPAIR or MUMUPRIM the meaning of What(1) and What(2) change but in > Flair, only when selecting MUMUPAIR the WHATs of PHOTONUC card change > whereas for SDUM=MUMUPRIM, Flair shows the same WHATs as SDUM=ELECTNUC. > > What are the correct meanings of WHATs for SDUM=MUMUPRIM? > > Best Regards > Hamideh > >
This archive was generated by hypermail 2.3.0 : Tue May 25 2021 - 18:49:06 CEST