Re: question about AUXSCORE card + dose

From: <Andrea.Mairani_at_mi.infn.it>
Date: Thu, 9 Jul 2009 12:43:08 +0200 (CEST)

Dear user,
about
"If I want to measure the DOSE deposited by only photon and only
electron how can I measure it with USRBIN card ?"
See the information written in the manual for the AUXSCORE card:

Examples:
*...+....1....+....2....+....3....+....4....+....5....+....6....+....7....+....8
 USRBIN 10.0 208.0 -50.0 10.0 10.0 10.0Ene.p
 USRBIN -10.0 -10.0 -10.0 100.0 100.0 100.0&
 AUXSCORE 2.0 1.0 1.0
 * The above AUXSCORE card will filter the energy scoring of the
 * USRBIN card to only the energy that is deposited by protons

In your input you've used:
USRBIN 10.0 228.0 -86.0 35.0 35.0
133.0ElectronB
USRBIN -35.0 -35.0 98.0 70.0 70.0 70.0 &
USRBIN 10.0 240.0 -87.0 35.0 35.0
133.0ElectronB
USRBIN -35.0 -35.0 98.0 70.0 70.0 70.0 &
AUXSCORE 2.00 3.0 6.0 7.0 AMB74

I think that you've to change the:
AUXSCORE 2.00 3.0 6.0 7.0 AMB74
in:
AUXSCORE 2.00 3.0 6.0 AUXSCORE
      2.00 3.0 7.0 AMB74
In this way, you've the dose due to electrons in ***fort.86 and the
equivalent dose due to elctrons in ***fort.87.

Ciao
Andrea
Received on Thu Jul 09 2009 - 15:22:56 CEST