From: <wurth_at_ipno.in2p3.fr>
Date: Wed, 25 Aug 2010 09:22:59 +0200

Hello Vadim,

Using DOSE-EQ =3D 240.0 gives you results in pSv/primary.
By means of DCYSCORE option, all results are expressed per unit time and
because you set a number of primaries in your IRRPROFIle card, you will
get results in pSv/s.
Then the conversion in mSv/h is obsious as you said.

Hope it helps.

Best regards.

Sebastien.

Le 23/08/2010 19:33, Vadim Talanov a =E9crit :
> Dear FLUKA experts,
>
> Sorry for a maybe strange/silly question:
>
> Let's define a USRBIN-ing to score dose equivalent through particle ty=
pe
> 240.
>
> Combining definition of particle code 240 at manual page 45 and Note 1=

> for DCYSCORE at page 86 tells that the result will be in [pSv/s] (?).
>
> However, at page 45 it is said to be also "per primary".
>
> Which "primary" is meant? Is there any relation to beam intensity and
> irradiation interval defined in IRRPROFIle?
>
> Simply: to what factor (if any) should be the USRBIN quantities
> normalized to get [mSv/h] after given irradiation period and decay tim=
e
> (apart from the obvious conversion of units)?
>
> Cheers,
> Vadim
>
>
>