Re: Why are the energy internals wrong?

From: <Andrea.Mairani_at_mi.infn.it>
Date: Fri, 11 Mar 2011 15:01:48 +0100 (CET)

Dear User,
  There is nothing wrong with your input.
FLUKA handles the generalized particle BEAMPART (Primary (source or beam)
particles) in a general way, i.e., if your primary particle is a neutron
it will give you also the information about the low energy neutrons
following the multigroup energy bins.
Ciao
Andrea

> Dear FLUKA experts,
> When I use USRBDX card with energy internals of 50 to score the
> beampart, but the output results with energy internals of 256 but not 50.
> What is wrong with my inputs?
> *
> ..+....1....+....2....+....3....+....4....+....5....+....6....+....7....+....8
> USRBDX -1.0 BEAMPART -49.0 CFR2 CFR3 1.0
> Beam
> USRBDX 1.6 1.0E-6 50.0 6.283185 0.0 1.0
> &
>
> The results is:
> # Detector n: 2 Beam (integrated over solid angle)
> # N. of energy intervals 256
>
>
> Thank you in advance!
>
> Hantao
> Jing
> 2011-3-8
>
Received on Fri Mar 11 2011 - 15:56:46 CET