Re: residual nucleus infomation

From: Mary Chin <mary.chin_at_cern.ch>
Date: Mon, 28 Jan 2013 20:53:31 +0100

Hi Shirley,

The two will not match when multigroup transport is in operation because
it is non-analog. Outside multigroup transport, the correspondence should
be there, but not necessarily at a call-by-call level. USDRAW is called
per collision, whereas USRRNC is called when a resnuc stops. Following a
collision a product may be transported, and will have its USRRNC call only
when it finally stops.

:) mary


On Sun, 27 Jan 2013, Shirley Li wrote:

> Hi Mary,
> Thanks! I added looking over NP and NPHEAV to get all the products in mgdraw. For isotopes like heavier
> than He, I count the number from either (ICRES, IBRES) or (ICHEAV, IBHEAV) from USDRAW. Now most of the
> isotopes number match between the two routines! :) However, some of the isotopes like 9Be, 11B numbers
> still mismatch by several percent. And, I get much more 13C from mgdraw than from usrrnc.
>
> I attached my inputs. Did I miss something in the loop in mgdraw?
>
> Thank you so much!
>
> Shirley
>
> On Sat, Jan 26, 2013 at 5:34 PM, Mary Chin <mary.chin_at_cern.ch> wrote:
> Hi Shirley,
>
> If we take the following collision as an example:
> p + 12C -> 7Be + n + p + a
>
> 7Be, 1H and 4He are going to get scored as RESNUCLE i.e. we get three out of a single
> collision. USDRAW is called once. USRRNC is called three times.
>
> If we try to print out from a USDRAW call, without any looping (over an array or something),
> we can't possibly get more than one output.
>
> To do the cross-check you intend to, I would loop through NP and NPHEAV in USDRAW to get the
> full suite of products following a collision. (I have done that before, they matched all
> right!)
>
> :) mary
>
>
> On Sat, 26 Jan 2013, Shirley Li wrote:
>
> Hi Mary,
> Thank you very much for your explanation!
>
> So, if I check ICRES from mgdraw.f and IZ from usrrnc, should I expect exactly
> the same number? I'm
> running 1000 muons through oil (CH2) to get isotope production. I print out
> ICRES, IBRES and WTRACK
> from mgdraw.f and IZ, IA, WEE from usrrnc.f. However, the numbers don't always
> match. E.g., I got 20
> 7Be from mgdraw.f and 33 7Be from usrrnc.f. I understand that I can get isotope
> production from
> RESNUCLEi scoring, but I just want to make sure that everything is consistent.
> Thanks a lot!
>
> Shirley
>
>
> On Fri, Jan 25, 2013 at 5:02 PM, Mary Chin <mary.chin_at_cern.ch> wrote:
> Dear Shirley,
>
> ICRES is a variable in RESNUC, which is an include file.
> IZ is an argument for USRRNC, which is a subroutine.
>
> ICRES will remain undefined unless the user routine contains the line:
> INCLUDE ‘(RESNUC)’
> Incidently, in the usrrnc.f template distributed, this line is absent.
>
> If IZ is already available as an argument in usrrnc.f, why would one
> attempt/wish to use
> ICRES instead? One would use ICRES, for example, in mgdraw.f, where the
> atomic number is
> not readily available as an argument.
>
> :) mary
>
> On Thu, 24 Jan 2013, Shirley Li wrote:
>
> Dear FLUKA users,
> I'm not sure what's the difference between ICRES (residual nucleus
> atomic
> number) in RESNUC and IZ
> (also residual nucleus atomic number) in usrrnc.f. Could anyone
> explain this
> to me?
>
> Thank you very much!
>
> Best,
> Shirley
>
Received on Tue Jan 29 2013 - 09:52:08 CET