(no subject)

From: Francesco Cerutti <Francesco.Cerutti_at_cern.ch>
Date: Wed, 18 Nov 2009 19:33:18 +0100

=09<fluka-discuss_at_fluka.org>
Subject: Re: depth distribution of heavy ions
In-Reply-To: <4f31bf280911180642h5e1727e3ia23765f225a55fd9_at_mail.gmail.com>
Message-ID: <alpine.LFD.2.00.0911181919320.4263_at_localhost.localdomain>
References: <4f31bf280911180642h5e1727e3ia23765f225a55fd9_at_mail.gmail.com>
User-Agent: Alpine 2.00 (LFD 1167 2008-08-23)
MIME-Version: 1.0
Content-Type: multipart/mixed;
=09boundary=3D"8323328-1267961517-1258569198=3D:4263"
X-CERN-Reverse-DNS: cernfe13.cern.ch
X-Greylist: Sender IP whitelisted, not delayed by milter-greylist-4.0 (smtp=
1.mi.infn.it [192.84.138.69]); Wed, 18 Nov 2009 19:29:05 +0100 (CET)
Sender: owner-fluka-discuss_at_mi.infn.it

--8323328-1267961517-1258569198=3D:4263
Content-Type: text/plain; charset=3D"UTF-8"; format=3Dflowed
Content-Transfer-Encoding: 8BIT

Hi,

as we already discussed (see=20
http://www.fluka.org/web_archive/earchive/new-fluka-discuss/2554.html)
at so low energies - for which one has ranges of the order of microns=20
and is easily under the Coulomb barrier, depending on the beam/material=20
nuclei - the role of nuclear interactions tends to be negligible and the=20
BME event generator is not at all relevant. What matters here is the=20
stopping power evaluation and for that refer to the quoted message

regards
Francesco

**************************************************
Francesco Cerutti
CERN-EN/STI
CH-1211 Geneva 23
Switzerland
tel. ++41 22 7678962
fax ++41 22 7668854

On Wed, 18 Nov 2009, Ercan Pilicer wrote:

> hi Andtrzej,
>
> that energy does not cover fluka range (up to 100MeV/n).
> you need BME option which is not implemented yet as far as i know.
> but to get dose depth,
>
> 1. link dpmjet with fluka
> 2. run your simulation with nuclear interactions is on
> 3. usrbin scoring
> 4. use flair to get dose-depth along beam axis (1d histo)
>
> ciao
> e.
>
>
> On Wed, Nov 18, 2009 at 11:55 AM, Andrzej Wojciechowski
> <andrzej_at_cyf.gov.pl> wrote:
>> Dear FLUKA users
>> How can I calculate the heavy ion of depth distribution implantated into
>> target? Heavy ion beam energy -3Mev /nucleon.
>> Kind regards
>> Andtrzej
>>
>>
>
>
>
> --=20
> =3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=
=3D=3D=3D=3D=3D=3D
> ()".'."() Ercan Pilicer
> ( (T) ) Uludag University, Turkey
> (=C3=B6) (=C3=B6) High Energy Physics Department