Dear User,
as reported in the AUXSCORE description. You can calculate the ambient
dose equivalent as:
USRBIN 10.0 DOSE-EQ -50.0 10.0 10.0 10.0DoseEq
USRBIN -10.0 -10.0 -10.0 100.0 100.0 100.0&
AUXSCORE USRBIN DoseEq AMB74
* Score ambient dose equivalent in a Cartesian mesh from all particles
I hope that this helps,
Andrea
> Below I attached my input file. I need to calculate equivalent DOSE
> outside
> of concrete box.
> As I understood from discussions I need switch on USRBIN card with part
> type set DOSE-EQ that gives Dose measured in pSv/primary. I also plotted
> 1D
> projection of DOSE vs distance from the radiation source using data of
> USRBIN card.
> Can someone with experience take a look and say am I did wrong or right?
>
> Is it required switch on AUXSCORE card and set conversion coefficients
> for
> each USRBIN card or it is optional and using USRBIN with part: DOSE-EQ is
> sufficient for getting DOSE?
>
>
> Thanks!
>