    Defines an irradiation profile for radioactive decay calculations

     See also DCYTIMES, DCYSCORE, RADDECAY, RESNUCLEi

     
WHAT(1)
= length of a newly defined irradiation interval (in s) > 0.0 : a new interval is added with length
WHAT(1)
= 0.0 : ignored < 0.0 : the last defined interval (if any) is deleted
Default
= no new irradiation interval is defined
WHAT(2)
= beam intensity of the newly defined (see
WHAT(1)
) irradiation interval >= 0.0 : beam intensity in particles/s (0 is accepted) < 0.0 : considered as 0.0
Default
: 0.0 particles/s
WHAT(3)
= the same as
WHAT(1)
WHAT(4)
= the same as
WHAT(2)
WHAT(5)
= the same as
WHAT(1)
WHAT(6)
= the same as
WHAT(2)
SDUM
= not used
Default
(option IRRPROFIle not given): no irradiation interval is defined
Note:
Several cards can be combined up to the desired number of irradiation intervals. Decay times as requested by DCYTIMES commands will be calculated from the end of the last one. Scoring during irradiation can be obtained giving negative decay times in DCYTIMES
Example:
*...+....1....+....2....+....3....+....4....+....5....+....6....+....7....+....8
IRRPROFILE 1800. 1.5E12 250. 3.E10 4500. 4.2E12
* The profile defined consists of 1800 s of irradiation at an intensity of
* 1.5E12 particles/s, followed by 250 s at low intensity (3.E10 particles/s),
* and then a third 4500 s interval at 4.2E12 particles/s