Re: [fluka-discuss]: Scoring DOSE-EQ and RZ binning

From: Answers <answers_at_pcfluka.mi.infn.it>
Date: Sat, 2 May 2020 18:07:28 +0200 (CEST)

Hello
About EMFCUT: if you do not set it, it will be set according to the
DEFAULT chosen (see in the manual). You can also check in the .out file.

Setting EMFCUT to the beam photon energy as in your input
will stop all electrons as soon as they are produced.

Yu can place usrbins also on the two ends of the cylinder, thin in z. Or
use USRBDX.

Regards
P



On Thu, 23 Apr 2020, Raksha Rajput wrote:

>
> Dear Experts,
>
> I am new to the use of FLUKA, attempting to use it for the calculating the
> dose rates outside the shielding. Radiation source is a photon source.
>
> I have attached the input file and the results obtained.
>
> It would be nice if you can comment on the correctness of the input written.
>
> I am not sure on the use of EMF thresholds. I understand that EMFCUT should
> be always be put with DEFAULTS-PRECISIO, but how about using it with EMCASA,
> as the difference is not much with and without EMFCUT (both results are of
> the order of 10E-09).
>
> How should I score on the top surface of the shield ( axial direction of the
> cylindrical source) ?
>
> Thanks so much in advance.
> Regards,
> Raksha R.
>
>
>
>
>
>
>