[fluka-discuss]: Inconsistency in absorbed dose values calculated using LET spectra and USRBIN

From: Panthi, Rajesh <rpanthi_at_ostatemail.okstate.edu>
Date: Mon, 12 Sep 2016 15:27:05 -0500

Dear FLUKA users,


Could you please help me with the following problem?


I want to calculate the LET spectra at different depths within Polyethylene
using 1GeV/n Silicon beam. Once the LET spectrum is scored at a certain
position within a medium, we can use it to calculate the absorbed dose at
that position. We can also score the absorbed dose directly in the same
depths by means of USRBIN card.

[image: Inline image 1]

However, the values of absorbed dose at the certain position calculated
from these two different methods, one using LET spectra and other scored by
USRBIN, do not agree with each other. I have compared both the absolute
values and normalized values. I am wondering if I am missing anything
specific in the calculation for this energy of beam (1GeV/n).

Below are the main FLUKA card options that I have used in my input file
besides the beam and geometry definitions.



DEFAULTS==> NEW-DEFA

PHYSICS==> EVAPORAT, New Evap with heavy frag

PAIRBREM==> Act: Both, e-e+ Thr: 0.0, y Thr:
0.001

                       Mat: AIR to Mat: POLYETHY

IONTRANS==> Transport: HEAVYION

USRYIELD==> Type: Yield ie: Particle LET,
                      ia: Particle charge

                        Part: HEAVYION, Yield:
,

                        Min1: Max1: 500

                        Min2: Max2: 100

                        Kind: d2N/dx1dx2 Mat: Water

USRBIN==> Type: X-Y-Z, Part: DOSE


I have used "ldpm3qmd" while compiling.



Kindly,


Rajesh Panthi