Re: FLUKA: Max. number of USRBIN binnings
paola sala wrote:
>
> Please check all your binning definitions ( the one you sent is n.66, you
>must
> have 65 usbin before ! )
> control the alignment, and be sure there are no "tab" characters.
> Check also your geometry
> Paola
Hi Paola,
Well, I indeed had a wrong syntax in my input USRBIN definition
(mis-alignment...)
By the way, I also debugged my geometry and I have some :
*** Region # 27 Dnear according to no overlapping ORs ***
*** Region # 53 Dnear according to possible overlapping ORs ***
*** Region # 56 Dnear according to possible overlapping ORs ***
messages. Are those errors or just warnings ?
Anyway, thanks again for your kind help,
--
Dr. Laurent APHECETCHE (mailto:aphecetc@in2p3.fr) | TAPS/PHENIX/ALICE
SUBATECH-Ecole des Mines de Nantes-4 rue Alfred Kastler-44070 NANTES
cedex 03
TEL (+33/0) 2 51 85 84 17 - FAX (+33/0) 2 51 85 84 24 (France)
http://www-subatech.in2p3.fr/~photons -
http://www.phenix.bnl.gov/~aphecetc
Partial thread listing:
FLUKA: FLUKA discussion list,
Federico Carminati